Skip to content

RTS-X Certifications

The RTS-1 and RTS-2 controllers meet major international standards.

Product Markings

RTS-X controllers are manufactured and shipped with the following certification marks.

Image title
Marking Description
FCC
Class B
The FCC Class B marking indicates that a digital device has been tested and found to comply with strict radio frequency emission standards for use in residential environments to prevent interference with other devices and broadcast transmissions.
CE The CE mark is a mandatory certification mark that indicates a product complies with all applicable European Union health, safety, and environmental protection requirements, allowing it to be sold freely within the European Economic Area.
UKCA The UKCA (UK Conformity Assessed) marking is the British product marking used for goods being placed on the market in Great Britain (England, Wales, and Scotland), indicating that a product conforms to the applicable UK legislative requirements following its departure from the European Union.
RoHS The RoHS (Restriction of Hazardous Substances) directive restricts the use of specific hazardous materials—such as lead, mercury, and cadmium—in the manufacture of various types of electronic and electrical equipment to protect human health and the environment.
CAN ICES-003 The CAN ICES-003 (or ICES-003) marking is the Canadian equivalent to FCC standards, indicating that a digital apparatus complies with Innovation, Science and Economic Development (ISED) Canada’s requirements for limiting radio frequency interference.

Electromagnetic Compliance (EMC) Testing

The following is a non-exhaustive list of EMC immunity testing conducted on the RTS-X controllers by an independent, certified laboratory.

Standard Description Test Parameters Performance Criteria Met
IEC 61000-4-2
EN 61000-4-2
Electrostatic Discharge +/-8kV Air Discharge
+/-4kV Contact Discharge
A
A
IEC 61000-4-3
EN 61000-4-3
ENV50140/240
Radiated RF Immunity 3 V/m, 80-100MHz, 1kHz AM modulation
3 V/m, 1.4-6.0GHz, 1kHz AM modulation
A
A
IEC 61000-4-4
EN 61000-4-4
Electrical Fast Transient +/-1kV on AC/DC lines
+/-0.5kV on I/O lines
B
IEC 61000-4-5
EN 61000-4-5
Surge Withstand Immunity +/-2kV Common Mode on AC Lines
+/-1kV Differential Mode on AC Lines
+/-1kV Common Mode on I/O Lines > 30m
+/-0.5kV Common & Differential Modes on DC Lines >10m
A
A
A
A
IEC 61000-4-6
EN 61000-4-6
ENV 50141
Conducted RF Immunity 3 V, 0.15-80 MHz, 1kHz 80% AM modulation on AC Lines, DC Lines & I/O Lines > 3m A
IEC 61000-4-8
EN 61000-4-8
Magnetic Field Immunity 50 Hz, 3 A/m A
IEC 61000-4-11
EN 61000-4-11
Voltage Dips
Voltage Dips
Voltage Dips
Interruptions
0% for 0.5 cycles
0% for 1 cycle
70% for 25 cycles
0% for 250 cycles
B
B
C
C
IEC 61000-3-3
EN 61000-3-3
Voltage Fluctuation and Flicker in Low-Voltage Supply Systems Voltage Fluctuation
Flicker
PASS
PASS

The following is a non-exhaustive list of EMC emission testing conducted on the RTS-X controllers by an independent, certified laboratory.

Standard Description Test Parameters Performance Criteria Met
IEC 61000-6-3:2021
EN 61000-6-3:2021
Conducted Emissions
Radiated Emissions
150kHz to 30MHz
30MHz to 6GHz
B
B
IEC 61000-3-2
EN 61000-3-2
Harmonic Current Emissions Class A (Other) PASS
FCC PART 15, SUBPART B 15.109(a), Class B Radiated Emissions from Computing Devices (Digital Devices) 30MHz to 6GHz B
FCC PART 15, SUBPART B 15.107(a), Class B AC Power Line Conducted Emissions 150kHz to 30MHz B
ICES-003, Issue 7 Class B Table 2 & 4 Radiated Emissions from Computing Devices (Digital Devices) 30MHz to 6GHz B
ICES-003, Issue 7 Class B Table 1 AC Power Line Conducted Emissions 150kHz to 30MHz B